RSMAG

Electromagnetic flowmeter
Flow measurement for conductive liquids.
Dn from 25 to 200 mm.
Connections DIN 11851 and CLAMP DIN 32676.
Measurement accuracy: ± 0.2%; ± 0.5%.
PFA coatings.
Power supply 85 ÷ 265Vac;12Vdc;24Vdc;24Vac.
Datalogger on USB pendrive.
Removable O-LED display module.
Remote control via Smartphone.

Description

RSmag flowmeters are suitable for applications in food and pharmaceutical industries. DIN or Clamp ISO 2852 process connection are suitable for applications with milk, beer or other drinks. Manufactured completely in stainless steel with the option for PFA lining makes RSmag suitable for pharmaceutical application.

RSMAG

Additional information

Range di portata

RPmag is able to process signals from fluids with flow rates of up to 10m / s in both directions (bidirectional meter).

Dimensione/Rivestimento

PFA DN25 ÷ DN200

Materiale sensore

SS304

Custodia elettronica

Alluminio verniciato epoxy

Materiale elettrodi

AISI316L,
Hastelloy C,
Platinum,
Tantalum,
Titanium

Campo di misura

min. di 0,1m3/h ÷ magg. di 600m3/h600m3/h

Accuratezza

± 0,2% optional,
± 0,5% standard

Ripetibilità

± 0,1%

Conducibilità fluido

>5μS/cm

Alimentazione

85 ÷ 265 Vac, 24 Vac/dc, 12 Vdc

Consumo

typical 6W, max 8W

Temperatura di processo

compact version: < = 120°C,
remote version: < = 150°C or < = 180°C

Temperatura di stoccaggio

-40°C ÷ 85°C

Comunicazione digitale

Modbus o Hart (opz.)

Data Logger

Internal data logger to USB pen drive for flow measurements and analog inputs storing; the measurement storage interval can be set from 15 to 3600 seconds

Segnali di uscita

4 ÷ 20 mA: 0 ÷ 750 ohm load,
frequency: 0,1 ÷ 5000 Hz,
Impulsiva: open collector 24 Vdc pull-up o open collector galvanicamente isolata

Uscite allarmi

2 relays, 3A 230 Vac N.O (not available for 12 Vdc versions)

Segnali in ingresso

2 active analog inputs at 24Vdc for 2-wire transmitters connection and 1 digital input for external contact connection for integrated batch function restart and partial totalizer management

Portata inversa

allow measure reverse flow.

Test segnali in uscita

Current Source: Transmitter can be commanded to supply a specified test current between 4.0 and 20.0 mA.

Tempo di avvio

0,5 sec. da portata zero.

Cut-off di portata

Adjustable. Below selected value, instantaneous flow and outputs are driven to the zero flow rate signal level.

Umidità relativa

0÷100% RH at 65 °C, not condensing

Tempo di risposta (integr.)

Adjustable between 1 and 99 secondi

Grado di protezione

compact version IP67,
Convertitore IP67,
remote sensor version IP67 / IP68 (on request)

Anticondensa

Anti-condensation filter installed on converter.

Manuale Operativo

Download

CATEGORIE PRODOTTO
CAMPO DI APPLICAZIONE
go
DOWNLOAD
CONTATTI
Tel. +39 02 95328257
Fax +39 02 95328321
info@sgm-lektra.com